![]() | Containing latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .ZIP and use the SW-M0XXX.tar files, do not unpack these.
SW-M008-1.1.5.0 & SW-M010-1.1.5.0, based on version 1.1.4.7 withthe following major changes. Fix of UTC/Loc time addition of PSKPDPT1 and 2 to allow PSKPDPT sentences to be sent separately on each NMEA, allowing use of IR301 and other older repeaters. PSKPDPT now has a quality parameter BAM & ALF improvements improvements of LWE -450 messages Memory and slowdown bug fixes New manual Last Updated 11.4.2025 - a patch to allow downgrade from later versions | |
![]() | Some instruction for use with upgrade of Multi systems using the SKIPPER service software. <\BR> It is important that the software version in the screen and the electronic unit match. If you are replacing 1 unit , check you have the same software version, and if not update the older part. | |
![]() | SKIPPER software uses a number of Open source programs, under license type LICENSE.lgpl-2.1. This file explains and clarifies the use of the software under this license. | |
![]() | ||
![]() | ||
![]() | Copy this directory locally, this includes the latest software version, add other ESN200 PC version as required
The windows versions of the Multi software (Not web version) can be started using a script as follows Start the software manually, set the LAN settings Then use a script to start the window: Remove the windows border : -frameless-window , the program can be killed using alt+F4 Use the saved LAN settings : -load-net-interface Maximise the window : -maximize-window to save the current LAN settings: -save-net-interface Example to start automatically start multi_screen.exe -load-net-interface -maximize-window -frameless-window to start to select new LAN settings Start multi_screen.exe -save-net-interface -maximize-window -frameless-window | |
![]() | Software only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included | |
![]() | Software only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included | |
![]() | ||
![]() | The windows versions of the Multi software (Not web version) requires the ESNDrivers to be copied locally, and then this file can be copied into that directory Select the same software version as you are running on the display | |
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | ||
![]() | Software only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included | |
![]() | Software only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included | |
![]() | ||
![]() | ||
![]() | Containing latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .RAR and use the SW-M0XXX.tar files, do not unpack these.
SW-M010-1.1.2.0 & SW-M008-1.1.2.0, fixed issues with ALR, New EPV remote control features, Fixes on Printer parameters, New Synch - ready to ping, - New Manual SW-M010-1.1.0.0 & SW-M008-1.1.0.0 Complient with IEC62923 BAM standard, and IEC61162-450. Many changes - check the manuals New text printer added Epson TM-T20III SW-M010-1.0.7.0 & SW-M008-1.0.7.0 Added LAN printer(vis service software or APP) and ML1120 printer. Improvements of Diagnostics and bottom detection algorithm Added Transducer KMS5018 selection, added options for DPT Max range, added Multiplex mode for ch1 and ch2 for using 2 transducers with the same frequency, extended internal history to 24h SW-M010-1.0.6.2 black box software with fixes for shallow water, bug fix of untis in DBS,DBT,DBK NMEA sentences SW-M010-1.0.6.1 black box software with fixes for shallow water, Diagnostic page, power failure on relay, Draft, NMEA2 input, other small bugs SW-M008-1.0.6.0 Display software with improvments in shallow water detection SW-M008-1.0.5.0 Display software with a number of gui improvements particularly in the diagnostics pages, SNR value (bottom detection threshold) can now be adjusted from scope screen. SW-M0010-1.0.5.0 black box software with a number of improvements in bottom detection , and fix for jumping depth to zero, new settings levels. SW-M008-1.0.4.0 Display software with a number of gui improvements and diagnostics improvements, improvement of TVG SW-M010-1.0.4.0 Electronic unit software with improvements in filter, depth detction, range, TVG and noise rejection Update using via LAN cable and Service software, ensure your PC is set up for static IP address in the same range as the unit (172.16.1.XXX) Last updated 30.08.2021 | |
![]() | ||
![]() | Containing latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .zip and use the SW-M0XXX.tar files, do not unpack these.
SW-M010-1.0.7.0 & SW-M008-1.0.7.0 Added LAN printer(vis service software or APP) and ML1120 printer. Improvements of Diagnostics and bottom detection algorithm Added Transducer KMS5018 selection, added options for DPT Max range, added Multiplex mode for ch1 and ch2 for using 2 transducers with the same frequency, extended internal history to 24h SW-M010-1.0.6.2 black box software with fixes for shallow water, bug fix of untis in DBS,DBT,DBK NMEA sentences SW-M010-1.0.6.1 black box software with fixes for shallow water, Diagnostic page, power failure on relay, Draft, NMEA2 input, other small bugs SW-M008-1.0.6.0 Display software with improvments in shallow water detection SW-M008-1.0.5.0 Display software with a number of gui improvements particularly in the diagnostics pages, SNR value (bottom detection threshold) can now be adjusted from scope screen. SW-M0010-1.0.5.0 black box software with a number of improvements in bottom detection , and fix for jumping depth to zero, new settings levels. SW-M008-1.0.4.0 Display software with a number of gui improvements and diagnostics improvements, improvement of TVG SW-M010-1.0.4.0 Electronic unit software with improvements in filter, depth detction, range, TVG and noise rejection Update using via LAN cable and Service software, ensure your PC is set up for static IP address in the same range as the unit (172.16.1.XXX) Last updated 04.03.2020 | |
![]() | Containing latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .zip and use the SW-M0XXX.tar files, do not unpack these.
SW-M010-1.1.0.0 & SW-M008-1.1.0.0 Complient with IEC62923 BAM standard, and IEC61162-450. Many changes - check the manuals New text printer added Epson TM-T20III SW-M010-1.0.7.0 & SW-M008-1.0.7.0 Added LAN printer(vis service software or APP) and ML1120 printer. Improvements of Diagnostics and bottom detection algorithm Added Transducer KMS5018 selection, added options for DPT Max range, added Multiplex mode for ch1 and ch2 for using 2 transducers with the same frequency, extended internal history to 24h SW-M010-1.0.6.2 black box software with fixes for shallow water, bug fix of untis in DBS,DBT,DBK NMEA sentences SW-M010-1.0.6.1 black box software with fixes for shallow water, Diagnostic page, power failure on relay, Draft, NMEA2 input, other small bugs SW-M008-1.0.6.0 Display software with improvments in shallow water detection SW-M008-1.0.5.0 Display software with a number of gui improvements particularly in the diagnostics pages, SNR value (bottom detection threshold) can now be adjusted from scope screen. SW-M0010-1.0.5.0 black box software with a number of improvements in bottom detection , and fix for jumping depth to zero, new settings levels. SW-M008-1.0.4.0 Display software with a number of gui improvements and diagnostics improvements, improvement of TVG SW-M010-1.0.4.0 Electronic unit software with improvements in filter, depth detction, range, TVG and noise rejection Update using via LAN cable and Service software, ensure your PC is set up for static IP address in the same range as the unit (172.16.1.XXX) Last updated 30.08.2021 | |
![]() | Containing latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .ZIP and use the SW-M0XXX.tar files, do not unpack these.
SW-M008-1.1.4.5 & SW-M010-1.1.4.5, Fixes in BAM, beeping, HBT and s:/d: order, bug fixes in GPS NMEA inputs Also including 1.1.4.4 Fixes in UTC and local clock, Logging of raw data, small bugs 1.1.4.3 Fixes in GPS local time, Line printer formats, Logging to USB and internal logging. 1.1.4.2 Bugfix transducer runtime screen for second channel showed first channel again (since 1.1.4.0) 1.1.4.1 Bugfix Display had problems showing clock for NMEA port with ZDA sentence (since 1.1.3.0) SW-M010-1.1.4.0 & SW-M008-1.1.4.0, - ETS50200 transducer is limited to 70% on 200kHz and 60% on 50kHz. ETN50 ETN200S Are limited to 70%, ETS050 is limited to 60%, ETS200 is limited to 70%. - Various bugfixes. Last Updated 28.10.2022 |