data//Software

CD401XX-SB Compact Display
CD401MR Update.zipProgram and Instruction of how to update a CD401MR-SB Multirepeater using a JTAG unit (must be purchased) or Chips that are inserted in the back. The Service software method currently does not work reliably for this update.
SW-C002-1.20 software for CD401XX-SB build1.binNew version following all current regulations EML / DL1 alarm is removed. MR now show ... instead of error if message is present, but not valid. Simulate S no longer flashes.
Updating the CD401MR-SB 14.07.2016.pdfInstruction of how to update a CD401MR-SB Multirepeater using a JTAG unit (must be purchased) or Chips that are inserted in the back. The Service software method currently does not work reliably for this update.
Older versions
CD401MR Update (2).zip
SW-C002-1.18 software for CD401XX-SB build0.binNew version including DL1, Alarm on NMEA (Speed logs) , 0.1 resolution. Remote trip reset, 1.18 includes bug fix for starting with lots of NMEA input. (black screen problem) and removes the default looping of input to output. Tsi can be reactivated in the menus if required. This update will probably not work for CD401MR-SB ( see seperate file)
CD40X-SC Compact display with LAN
SW M001 R1.63 SW for CD40X-SC Display.bin SW-M001 Software for CD40X-SC for DL1, Multi repeater
(Not for EML Compact or DL1 Compact (CD401XX-SB)

Current Version 1.63
Changes to the PSKPDPT sentences so that unit will select only channel 1 or channel 2 and not flip between them.
Version 1.62
CD401MR-SC Added
bug in PSKPDPT 1, 2, 3 messages.
Last updated 6.1.2023
SW M001 R1.63 SW for CD40X-SC Display.bin.zip
DL1 - Software for CD402 Compact display and JB70 Unit
DL1 Customer change notes.docxNew Features in DL1 1.61
-10kn limit removed
CN2 bug fix for all versions
Web service password added to master reset
New Features in DL1 1.59
• New filter added to remove noise if on a single beam
• Web functions improved including run time screen
• Fix of test A – now passes in normal situations, even on large vessels :
DL1 Customer change notes.pdfNew Features in DL1 1.61
-10kn limit removed
CN2 bug fix for all versions
Web service password added to master reset
New Features in DL1 1.59
• New filter added to remove noise if on a single beam
• Web functions improved including run time screen
• Fix of test A – now passes in normal situations, even on large vessels :
SW M001 2 3 R1.61 DL1 SW for JB70 CD402 display and DL1 sensor .zipDL1 - Softwares for the DL1-Multi product, SW-M001-1.59, SW-M003-1.61 for the JB70D1-SA, SW-M002-1.05 for the DL1 sensor, last updated 03.03.2020
Older versions
SW M001 2 3 R1.59 DL1 SW for JB70 CD402 display and DL1 sensor .zip
DL2 - Software for screen and JB70 Unit
Instruction for upgrade DL2.pdfSome instruction for use with upgrade of DL2 systems using the SKIPPER service software. It is important that the software version in the screen and the electronic unit match. If you are replacing 1 unit , check you have the same software version, and if not update the older part.
LICENSE.lgpl-2.1.pdfSKIPPER software uses a number of Open source programs, under license type LICENSE.lgpl-2.1. This file explains and clarifies the use of the software under this license.
SW for DL2 1.2.1.2 (HF) w manuals.zip
Software SW-M004/5 1.2.1.2 (26.09.2022)
with following changes:

fix of problem with acknowledge and rebooting after upgrade

Software SW-M004/5 1.2.1.1 (07.09.2022)
with following changes:

fix of "NO COMMUNICATION"
fix of memory leak (restart of display/JB)
Note: There is a chance this upgrade may require a Factory reset of the system, we recomend you note the calibration settings before upgrading

Software SW-M004/5 1.2.1.0 with following changes:
fix of ALR alarm
fix of n: in UDP (LAN) coms
addition of EPV for simulation and standby and reverse
fix of diagnostic test, calibration status text, reset.

Software SW-M004/5 1.2.0.0 with IEC62923(2018) Size 36MB. This package includes a new more stable upgrader and is recomended.
To use this software upgrade service software to 1.92 or above, upgrade will normally have to be performed 2 times.
BAM Alerts compliant, alerts changed to be warnings. all can be individually disabled. New manual also avaialble.

- Changes in dual Display parallel version (requires long press to change and other bug fixes, for communication errors),
- Patch 2 for Total & Trip error (double distance error in previous versions)
- Patch 3 fix of loss of STW when passing North heading.
Patch 7 new filter and frequency changing algorithm and variuos bug fixes
Patch 8 Improved logging function, removal of autozip of files on usb, these should now be manually zipped before sending.
remove off as screen dimming level,
bug fixes on config saving, Incoming ALF/ACN and gui texts
removal of -0.0 possibility for better use with IR300
improvements in sensor upgrade functionality
SW-M004/5-1.1.2
- div bug fixes
Added Ground total and trip, with low integrity if bottom is lost
No communication fixes (due to multiple clocks or long input messages)
Patch 1 (1.1.2.1)
Parallel screens functions bug fix on older displays/OS
Package contains: 1) SW M004 for JB70 electronic unit, 2) SW M005 Graphic Display CU-M001-xx, Firmware upgrade is currently avalible for sensor (current is 3.04)
Last Update 26.09.2022
Older Versions
DL2 Software version 1.0.13 patch 4 23.08.2016 with manuals.zip
DL2 Software version 1.0.13 patch 4 23.08.2016.zipSoftware version 1.0.13 (Patch 4) for DL21 & DL2,
Fixes to allow the DL21 DL2 part to work in SOG only mode, also improves STW values to be within spec.
Contains SW-M005-1.0.13.4 for CU-M001-xx Display, SW-M004-1.0.13.4 for JB70, SW-M006-2.14 for sensor.
Changes of 1.0.13.2 to 1.0.13.4 stabilise the system with high NMEA input loads.
SW for DL2 1.1.1.8 (HF) w manuals NEW UPGRADER.zip Software version 1.1.1 for DL2 with high frequency - MUST BE USED WITH SERVICE SW V >1.91
- Changes in dual Display parallel version (requires long press to change and other bug fixes, for communication errors),
- Patch 2 for Total & Trip error (double distance error in previous versions)
- Patch 3 fix of loss of STW when passing North heading.
Patch 7 new filter and frequency changing algorithm and variuos bug fixes
latest version 1.1.1.8 03.03.2020
Patch 8 : Improved logging function, removal of autozip of files on usb, these should now be manually zipped before sending.
remove off as screen dimming level,
bug fixes on config saving, Incoming ALF/ACN and gui texts
removal of -0.0 possibility for better use with IR300
improvements in sensor upgrade functionality
Package contains: 1) SW M004 for DL2 JB70 Unit, 2) SW M005 Graphic Display CU-M001-xx 3) SW M006 FW for DL2 Sensor with high frequency for sensor SN > 170373
SW for DL2 1.1.1.8 (HF) w manuals OLD UPGRADER.zip Software version 1.1.1 for DL2 with high frequency - MUST BE USED WITH SERVICE SW V <1.90
- Changes in dual Display parallel version (requires long press to change and other bug fixes, for communication errors),
- Patch 2 for Total & Trip error (double distance error in previous versions)
- Patch 3 fix of loss of STW when passing North heading.
Patch 7 new filter and frequency changing algorithm and variuos bug fixes
latest version 1.1.1.8 03.03.2020
Patch 8 : Improved logging function, removal of autozip of files on usb, these should now be manually zipped before sending.
remove off as screen dimming level,
bug fixes on config saving, Incoming ALF/ACN and gui texts
removal of -0.0 possibility for better use with IR300
improvements in sensor upgrade functionality
Package contains: 1) SW M004 for DL2 JB70 Unit, 2) SW M005 Graphic Display CU-M001-xx 3) SW M006 FW for DL2 Sensor with high frequency for sensor SN > 170373
SW for DL2 1.1.2.1 (HF) w manuals NEW UPGRADER.zip Software version 1.1.1 for DL2 with high frequency This package includes a new more stable upgrader and is recomended.
To use this software upgrade service software to 1.92 or above, upgrade will normally have to be performed 2 times.
- Changes in dual Display parallel version (requires long press to change and other bug fixes, for communication errors),
- Patch 2 for Total & Trip error (double distance error in previous versions)
- Patch 3 fix of loss of STW when passing North heading.
Patch 7 new filter and frequency changing algorithm and variuos bug fixes
Patch 8 Improved logging function, removal of autozip of files on usb, these should now be manually zipped before sending.
remove off as screen dimming level,
bug fixes on config saving, Incoming ALF/ACN and gui texts
removal of -0.0 possibility for better use with IR300
improvements in sensor upgrade functionality
Latest version 1.1.2
- div bug fixes
Added Ground total and trip, with low integrity if bottom is lost
No communication fixes (due to multiple clocks or long input messages)
Patch 1 (1.1.2.1)
Parallel screens functions bug fix on older displays/OS
Package contains: 1) SW M004 for JB70 electronic unit, 2) SW M005 Graphic Display CU-M001-xx, Firmware upgrade is currently avalible for sensor (current is 3.04)
SW for DL2 1.1.2.1 (HF) w manuals OLD UPGRADER.zip
Latest version 1.1.2 with old upgrader, (to be used with service software <1.92)
Recomend use with new upgrader for better upgrade stability

- div bug fixes
Added Ground total and trip, with low integrity if bottom is lost
No communication fixes (due to multiple clocks or long input messages)
Patch 1 (1.1.2.1)
Parallel screens functions bug fix on older displays/OS
Package contains: 1) SW M004 for JB70 electronic unit, 2) SW M005 Graphic Display CU-M001-xx, Firmware upgrade is currently avalible for sensor (current is 3.04)
SW for DL2 1.2.0.0 (HF) w manuals NEW UPGRADER IEC62923.zipSoftware SW-M004/5 1.2.0.0 with IEC62923(2018) Size 36MB. This package includes a new more stable upgrader and is recomended.
To use this software upgrade service software to 1.92 or above, upgrade will normally have to be performed 2 times.
BAM Alerts compliant, alerts changed to be warnings. all can be individually disabled. New manual also avaialble.

- Changes in dual Display parallel version (requires long press to change and other bug fixes, for communication errors),
- Patch 2 for Total & Trip error (double distance error in previous versions)
- Patch 3 fix of loss of STW when passing North heading.
Patch 7 new filter and frequency changing algorithm and variuos bug fixes
Patch 8 Improved logging function, removal of autozip of files on usb, these should now be manually zipped before sending.
remove off as screen dimming level,
bug fixes on config saving, Incoming ALF/ACN and gui texts
removal of -0.0 possibility for better use with IR300
improvements in sensor upgrade functionality
Latest version 1.1.2
- div bug fixes
Added Ground total and trip, with low integrity if bottom is lost
No communication fixes (due to multiple clocks or long input messages)
Patch 1 (1.1.2.1)
Parallel screens functions bug fix on older displays/OS
Package contains: 1) SW M004 for JB70 electronic unit, 2) SW M005 Graphic Display CU-M001-xx, Firmware upgrade is currently avalible for sensor (current is 3.04)

Last Update 28.8.2021
SW for DL2 1.2.1.0 (HF) w manuals.zip
Software SW-M004/5 1.2.1.0 with following changes:
fix of ALR alarm
fix of n: in UDP (LAN) coms
addition of EPV for simulation and standby and reverse
fix of diagnostic test, calibration status text, reset.

Software SW-M004/5 1.2.0.0 with IEC62923(2018) Size 36MB. This package includes a new more stable upgrader and is recomended.
To use this software upgrade service software to 1.92 or above, upgrade will normally have to be performed 2 times.
BAM Alerts compliant, alerts changed to be warnings. all can be individually disabled. New manual also avaialble.

- Changes in dual Display parallel version (requires long press to change and other bug fixes, for communication errors),
- Patch 2 for Total & Trip error (double distance error in previous versions)
- Patch 3 fix of loss of STW when passing North heading.
Patch 7 new filter and frequency changing algorithm and variuos bug fixes
Patch 8 Improved logging function, removal of autozip of files on usb, these should now be manually zipped before sending.
remove off as screen dimming level,
bug fixes on config saving, Incoming ALF/ACN and gui texts
removal of -0.0 possibility for better use with IR300
improvements in sensor upgrade functionality
SW-M004/5-1.1.2
- div bug fixes
Added Ground total and trip, with low integrity if bottom is lost
No communication fixes (due to multiple clocks or long input messages)
Patch 1 (1.1.2.1)
Parallel screens functions bug fix on older displays/OS
Package contains: 1) SW M004 for JB70 electronic unit, 2) SW M005 Graphic Display CU-M001-xx, Firmware upgrade is currently avalible for sensor (current is 3.04)
Last Update 4.11.2021
Windows Version
DL2 Windows SW M005-1.2.0.0 (BAM version).exe
DL2 Windows SW M005-1.2.0.0 (BAM version).rar
SW M005 1 1 3 0 for windows.rar
SW M005 WIN R1.1.2.1.rar
SW M005 WIN ver 1 1 1 7.zip
Windows drivers.rarWindows version of display decompress the drivers into a folder on your PC, then copy into that folder the software .exe you require, and start the .exe from within the folder (or via a shortcut)
DL21 - Software for screen and JB70 unit on DL21
Change note for software DL21 system sw 1.0.13 to 1.0.15 Sensor 2.13 to 2.16.pdfChange notes from DL2 v 1.0.13 to 1.0.15
Instruction for upgrade.docxSome instruction for use with upgrade of DL1 DL2 and DL21 systems using the SKIPPER service software. It is important that the software version in the screen and the electronic unit match. If you are replacing 1 unit , check you have the same software version, and if not update the older part.
LICENSE.lgpl-2.1.pdfSKIPPER software uses a number of Open source programs, under license type LICENSE.lgpl-2.1. This file explains and clarifies the use of the software under this license.
SW for DL21 v 1.0.17 1.61 w manuals NEW UPGRADER - No alerts IEC62923.zip Version 1.0.17 INCLUDING NEW UPGRADER - ONLY TO BE USED WITH SERVICE SOFTWARE >1.91 Size 53MB Release 1.0.17.1 with improvments in Data Transfer DL1<->DL2 and internal communication management.
Upgrade will normally have to be performed 2 times
Removal of Alerts as required to meet IEC62923 BAM standard. system failure should be diagnosed using diagnostics page. New manual also available
Note downgrading from 1.1.X or 1.2.X (DL2) may cause problems, contact SKIPPER if you need to do this.
Last Update: 27.11.2021
instructions to upgrade DL21 15072016.pdfDetailed instructions of how to set up and commision a DL21 system in the SOG only mode.
Older versions
SW for DL21 DL2 v 1.0.14 w manuals.zip1.June-2018: Latest release of DL2 software, bug fixes, new features, improved STW 1.0.14 patch 5 with general improvements: 30.8.2018 bugfix for system alarm
SW for DL21 DL2 DL1 v 1.0.15 1.60 w manuals.zipUpdates improve communications between systems, and removal of extra unused buttons
DL1 bugfix of CN2 and DIAG A
SW for DL21 DL2 DL1 v 1.0.16 1.61 w manuals NEW UPGRADER.zip Version 1.0.16 INCLUDING NEW UPGRADER - ONLY TO BE USED WITH SERVICE SOFTWARE >1.91
Upgrade will normally have to be performed 2 times
Updates improve communications between systems, and removal of extra unused buttons
DL2 addition of ground distance, and various bug fixes, new manuals
DL1 bugfix of CN2 and DIAG A
SW for DL21 DL2 DL1 v 1.0.16 1.61 w manuals OLD UPGRADER.zip Version 1.0.16 for old Upgrader and Service software <1.90 Updates improve communications between systems, and removal of extra unused buttons
DL2 addition of ground distance, and various bug fixes, new manuals
DL1 bugfix of CN2 and DIAG A
Windows versions
SW M005 1 0 17 0 windows software.rar
SW M005 windows version R1.0.16.0.rar
Windows drivers.rarWindows version of display decompress the drivers into a folder on your PC, then copy into that folder the software .exe you require, and start the .exe from within the folder (or via a shortcut)
SW M005 1 0 17 1 windows software.zip
DL850X - Software for the 540kHz DL850 Doppler log (SN 07XXX-)
4 01 33 DL850 540 version.850UART driver bug has been fixed. With the heavy traffic, the byte in the output stream was lost sometimes.
DL850 software upgrade procedur May 2014A.pdf
Older versions
4 01 32 DL850 sw For 540kHz R4.01.32.EXERecomended upgrade of software for the DL850 display cabinet for the 540 kHz system. Includes bug fixes, a diagnostics screen and new speed indicator. Also a fix for the white screen problem See manual/ data bullitin for details
DL850 (540Khz) v 4 01 30 release.850
DL850 sw 4 01 31 For 540kHz.850
DL850X27 - Software for the 270kHz DL850 Doppler log
DL850 software upgrade procedur May 2014A.pdf
V 040409 DL850 270.EXE SW-D009 4.04.09 release notes 05 MAR 2021
Temperature reading bug fix..
1. Fixed error of Temperature switching between uncalibrated and calibrated temperature.
Older versions
V 040203 DL850 270.EXE
V 040303 DL850 270.exeSW-D009 4.03.03
Software with corrected diagnostic features and correction for the occasional white screen problem. See forum or data bullitins for more info.
V 040304 DL850 270.850SW-D009 4.03.04 DL850 270
Version with many improvements and some new features including remote trip reset.
V 040307 DL850 270.EXESW-D009 4.03.07 DL850N/D27 software for DL850 270 kHz
1 Bug fix, a missing ; in code meant that after production an error could occur that maid the gain curve wrong in bottom track mode. This could cause problems in some cases and can be seen by almost continuous flashing of LED800 on PV271 receiver card. Now fixed 2 Bug fix, During production the WT gain is changed, this was not updating in this version, now fixed
V 040307 DL850 270.zipSW-D009 4.03.07 DL850N/D27 software for DL850 270 kHz
1 Bug fix, a missing ; in code meant that after production an error could occur that maid the gain curve wrong in bottom track mode. This could cause problems in some cases and can be seen by almost continuous flashing of LED800 on PV271 receiver card. Now fixed 2 Bug fix, During production the WT gain is changed, this was not updating in this version, now fixed
V 040308 DL850 270.EXESW-D009 4.03.08. May 2015 DL850N/D27 software for DL850 270 kHz version.
1 Made NMEA output work at 1 second (previously went faster) 2 On upgrade, the Trip is correct.(previously changed to negative number over a certain value) 3 Standby and reboot fix to make this go quicker. (It slowed down in 4.03.03) 4 Fix of white area in diagnostic screen in night screen (June) 5 Bug fix of introduced problem with bootup with NMEA on input 6 Position from GPS. N-E swapped
V 040310 DL850 270.EXESW-D009 4.03.10 DL850N/D27 software for DL850 270 kHz version
1 Correction of Speed limit settings, The settings are now saved through a system restart.
V 040401 DL850 270.EXESW-D009 4.04.01 DL850N/D27 (Build August) software for DL850 270 kHz version
1 Addition of diagnostic for lost STW; 2 Addition of method to remove a single beam with error; 3 Removal of Low and high speed Alarms; 4 div. screen updates; For diagnostic information see databullitin SDB_DL850_19 Beam failure causing STW Error
V 040402 DL850 270.EXESW-D009 4.04.02 for DL850 270
1. Temperature instability bug fix 2. Delay between WT samples is increased 2x times for three shallowest ranges. ("Screen scope","Menu","WT min" is actually 300ms on all depth ranges when display showing 150ms) 3. The number of the channel, which is excluded from calculations is indicated on the status screen 4. Digitizing error fix. Digitizing was enabled at startup. Now it is disabled.
V 040403 DL850 270.EXESW-D009 4.04.03 for DL850 270
version, bug fix in trip counter.
V 040405 DL850 270.EXESW-D009 4.04.05 for DL850 270
Temperature compensation mechanism has been changed. 1. Removed all old switches, which were never used. 2. Implemented New button at Screen calibration, Menu 4, two beeps. [Temp comp] On/Off 3. When [Temp comp] On, both speed of sound in the water and in polyurethane are recalculated based on the present temperature. 4. When [Temp comp] Off, both speed of sound in the water and polyurethane are fixed and can be changed from the softkeys. 5. Two separate calibration tables are implemented and will be used according to the setting of the Temp comp parameter. 6. After upgrading the old calibration table will be saved, but the [Temp comp] will be forced ON with empty calibration table. 7. Note. There is no automatic detection of the temperature sensor malfunction. If this is a case, the [Temp comp] must be switched OFF.
V 040406 DL850 270.zip SW-D009 4.04.06 release notes. - Implemented New button at Screen calibration, Menu 4, two beeps. [Temp comp] On/Off - After upgrading the old calibration table will be saved, but the [Temp comp] will be forced ON with empty calibration table.
V 040408 DL850 270.EXE SW-D009 4.04.08 release notes 14 MAR 2019
Temperature compensation mechanism has been changed.
1. Fixed error of second calibration table memorizing.
2. Minor bug fixes
EF201 - Software for GDF201
GDF201 v 3 01 05.EXEAdd Checksum to NMEA outputs
Older versions
GDF201 v 3 01 03.EXE
EML224N- EML Graphic display
EML224 release notes.pdf
EML224 v1 28 03 release.EXE
Older versions
1 27 26(2) EML224.224SW-E001-1_27_26(2) SW for EML224 Changes, version 1.27.26, Feb 2014 UART driver bug has been fixed. With the heavy traffic, the byte in the output stream was lost sometimes. Changes, version 1.27.26, April 2014 release 2 Fix of com 2 crash when restarted with high load
1 27 21 EML224 Graphic cabinet R1.27.21.EXESoftware For the EML224 Graphic cabinet (Not Compact)
EML224 v1 28 02 release.EXESW-E001-1_28_02 SW for EML224 - Fix of Heading Error bug ; W-E001-1_28_01 SW for EML224 Changes, version 1.28.01, Feb 2017 Alarm Changes-removed softkey ScreenA speed HI/LO, Screen COM removed Type and alarm ID, Relay alarm to power failure. Demo Indication-changed indication to large S. NMEA Messages integrity checks-included intergrity check on the input of GDS. Screen Presentation-"No calibration present" does not flash, messages with low intergrity shown by yellow color COM, Panel keys are lit in Standby
SW-E001-1 27 25(3) SW for EML224(3).224SW version 1.27.25 including a new function to allow the display to show 1 Axis data, or data from a DL1 sensor
EML224S - EML Sensor
EML224 1 01 14.SFT
EN101C - Software for the GDS101
GDS Software upgrade instructions.pdf
GDS101 v 5 06 08.101GDS101, version 5.06.08 release notes 26th. November 2019 Bugfix of both VTG and HDT input in version 5.06.07 1. If HDT is present on the input, heading is displayed and stored in the history. 2. If VTG is presents on the input, COG is displayed and stored in the history. 3. If both VTG and HDT are present on the input – heading is being displayed and stored in the history.
Older versions
GDS101 v 5 06 03.EXEGDS101, sw version 5.6.03 Release notes. 10.09.2018 1. The instance number is added to ALC message, if the alert is not in inactive state. 2. Invalid NMEA input will appear in yellow in sceen 8 and on top of run time screen.
GDS101 v 5 06 04.EXEGDS101, sw version 5.6.04 Release notes. 11.1.2019 1.During printing in playback mode the date of recording is being print ed. (Earlier the current date was printed) 2.Printer bug fix. The text data was never update after printer start 3.Reduced paper advance after stopping printing.
GDS101 v 5 06 05.EXEGDS101, sw version 5.6.05 Release notes. 14 MAR 2019
1. Removed GPS time out in HISTORY MODE
GDS101 v 5 06 06.101GDS101, sw version 5.6.06 Release notes. 30 Jul 2019
1. Reduced power is applicable to all channels when produced as RP versjon (Simrad)
GDS101 v 5 06 07.101GDS101, version 5.06.07 release notes 12th. November 2019 1. If HDT is present on the input, heading is displayed and stored in the history. 2. If VTG is presents on the input, COG is displayed and stored in the history. 3. If both VTG and HDT are present on the input – heading is being displayed and stored in the history.
GDS101 V5 05 12.101
GDS101 V5 05 13.EXE
GDS101 V5 05 16.EXEGDS 101 Software, with clearer indication of the depth being displayed on screen (DBT,DBS,DBK) and corrected NMEA alarm protocol, Remote NMEA key press and bug fix of remote keyboard (Build 7 under test)
GDS101 V5 05 17.101SW-G010-505.17(6) GDS 101 Software, Software version 5.05.17, March 2014 1. German text and abbreviations according to the list. 2. Semaphores – to avoid fonts conflicts (Report from Eva) 3. RS232 TX driver – missing byte problem fix. 4. The global ParamValueStr size increase to 120 byte – to avoid overflow 5. NMEA string text output change – for proper output of the messages with wrong checksum 6. Change of the Epson printer name 300->350 (Report from Eva) 7. Change of the position of the texts in the lower text line – to avoid overlap (Report from Eva) 8. Change of the font in the digital indicator – removed stripes. Software version 5.05.17, April 2014 (release 6) Fix of com 2 failure when rebooted with heavy input load Software version 5.05.17, June 2014 (release 7) number of characters accepted on NMEA input extended to 82 (from 79) to meet standard
GDS101 V5 06 01.EXESoftware update with changes for IEC62288:2014 and MSC302 (ALF alarm). See release file for details
GDS101 V5 06 01 Changes.docxChange notes for version GDS101 5.06.01
GDS101 V5 5 14.101
GDS101 V5 5 19.EXEGDS101, sw version 5.5.19. Release notes. 1. Deep and shallow alarms are separated. They have individual ID, NMEA sentence text field and timing of the change event. 2. Additional screen (number 11) has been added. It contains all alarm related functions. 3. Shallow alarm can be disabled by setting its value to 0. In this case the shallow alarm ALR message will not be sent on the NMEA output. Factory default is 0. 4. Deep alarm can be disabled by setting its value to max range (1600m). In this case the deep alarm ALR message will not be sent on the NMEA output. Factory default is max range. 5. CAT A / CAT B function added in “Screen 11”.The default alarm processing type is CAT A were “Shallow alarm” will only be silenced by external acknowledge. Acknowledged only local. 6. In CAT A Alarm relay is only “Power failure” alarm
EN102C - Software for the GDS102
GDS102v 1 13 05.10216.08.2019 - 1) Printer bug fix - Marker print 2) The REV COUNTER is added to ALC message, if the alert is not in inactive state. 3) The instance number is added to ALF message, Instance number is empty.
Older versions
01 12 09(3) GDS102.102SW-G006-01.12.09(3) GDS102, version 1.12.9 release notes in 1.12.07 1. Priority of the indicated depth has been changed. If the offset is set non-zero, depth below keel will always be indicated regardless of the draft setting. 2. One more text field is added below the depth indication on the screen. This is to provide clear indication which depth value id being indicated: below transducer/below the surface/below the keel. 3. NMEA Alarm changes. If the valid AKN message received – the status in the ALR message is changed to A. (Acknowledged) 4. Screen presentation Alarm changes. The alarm label always keeps red color when in alarm conditions. The alarm label is blinking if alarm is not acknowledged (from the display unit keyboard, externally or from NMEA line) GDS102, version 1.12.09 release notes Feb 2014 1. Detected amplitude is outputted on the ana channel #3 (“Trygve Braarud” feature) 2. Minimal TX pulse width is increased to 300us 3. Number of averaged digitized samples is reduced from 10 to 5 4. Blanking period is increased to 60cm (High F) and 80cm (Low F) 5. Default GAIN settings changed to 55% (High F) and 41% (Low F) 6. Default TVG settings changed to 65% (High F) and 60% (Low F) GDS102, version 1.12.09 release 2 notes April 2014 Fix of bug of crash of output com 2 when rebooted with heavy load on com 2 input GDS102, version 1.12.09 release 3 notes May 2014 Bug fix, Change of frequency in software, causes change of pulse length, this did not always follow – fixed Bug fix, Top information line moved down 3 pixels to be compatible with new screens DG81.
1 12 10 (2)GDS102.102Fixed shallow water issues. system detected surface as bottom in some cases • Jumping amplitude diagnosed to mixer issues. Slight frequency differences causing filter to overreact (shown a little extreme when using simulator with slightly different frequency return) –change to be made in PLD 14 • Swapped N and E on GPS line • To check hanging text on NMEA on coms screen when changing from output to input
1.13.01 GDS102 changes.docxRelease notes for the software version GDS102 v1.13.01
1.13.01 GDS102.102Changes for autorange, and IEC62288:2014 and MSC302 (ALF) See release file for details
1.13.02 GDS102.zipFixed an issue where printing in playback mode printed the current date instead of date of recording.
1 12 7(2) GDS102 1.12.7.EXEGDS102, version 1.12.7 release notes 1. Priority of the indicated depth has been changed. If the offset is set non-zero, depth below keel will always be indicated regardless of the draft setting. 2. One more text field is added below the depth indication on the screen. This is to provide clear indication which depth value id being indicated: below transducer/below the surface/below the keel. 3. NMEA Alarm changes. If the valid AKN message received – the status in the ALR message is changed to A. (Acknowledged) 4. Screen presentation Alarm changes. The alarm label always keeps red color when in alarm conditions. The alarm label is blinking if alarm is not acknowledged (from the display unit keyboard, externally or from NMEA line)
GDS102 1 12 6.EXE
GDS102 v 1 12 4.EXE
GDS102v 1 13 03.zip03.1.2.2018 - 1) During printing in playback mode the date of recording is being printed. (Earlier the current date was printed) 2) Printer bug fix. The text data was never update after printer start 3)Reduced paper advance after stopping printing.
ESN100 - Software for ESN100 echosounder
LICENSE.lgpl-2.1.pdfSKIPPER software uses a number of Open source programs, under license type LICENSE.lgpl-2.1. This file explains and clarifies the use of the software under this license.
SW M007 1 1 0 10 ESN100.tar
ESN100 1.1.0.10 (16.2.2024)
ALC alert format is corrected to remove extra ,,, at the end of the format.

ESN100 1.1.0.9 (26.05.2023)
Correction of Local or UTC clock, if the offset in ZDA is -00
Added a variable number (8) in message PSKPDPT for the number of sequential fully qualified pings (0-9) this can be used as quality of the signal
ESN100 1.1.0.8 (14.11.2022)
correct error in UDP (sending too many messages on different groups)
Added a fixed number (8) in message PSKPDPT for signal strength
ESN100 1.1.0.7 (3.11.2022)
fix of clock input
adjust ment of max ping to prevent power baterry emptying
Remove noise from screen introduced in 1.1.0.5
ESN100 1.1.0.6 (3.10.2022)
bug fix of noise on screen
improvement of deep water power output in 200kHz

ESN100 1.1.0.6 (30.09.2022)
Added HBT on second Alarm UDP group
bug fix of beeper beeping unevenly, particularly when range changes.

ESN100 1.1.0.5 (23.09.2022)
Improvement of logging function - longer logging period of raw data
Memory/CPU over useage corrected
Noise test summary on diagnostic page is corrected
UDP s: d: order is now not important
UTC/LOC time is corrected
ESN100 1.1.0.4 bugfix
Transducer 2 shows Transducer 1 information (from 1.1.0.1)
Problem with receiveing ZDA clock (from 1.1.0.1)
ESN100 1.1.0.2 bugfix
Removed occasional popup for 2 transducers
ESN100 1.1.0.1 bugfix
speed of sound function changes
addition of EPV standby and remote control
Recomended Software update for ESN100 1.1.0
Includes the new Alert standard IEC62923 BAM standard with alerts. A new Manual and Type certificate is also available.
Previously 1.1.0.0
This is a new type of upgrader and the files do not need to be unzipped. Use the latest skipper service software and go to ESN100 tab for further instructions.
1.0.4.0 changes History to 24h (previously 12h), adds printer menu, and option to turn on and off the LAN printer (runs with service software or ESN print and archive software that can be downloaded from the website), and gives option to download the previous 2 days history.
New manual also available
New service software 1.88 , will also download a stand alone .exe in the skipper/service software folder, ESN print and archive software V1.0.1 that can run in stand alone mode
1.0.3.0 included improvements in Auto functions and a number of bug fixes
Last Update 16-2-2024
Equivilent Software for Windows
ESN100 PC Version SW M007-1.1.0.7.exeSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN100 PC Version SW M007-1.1.0.7.zipSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN100 PC Version SW M007-1.1.0.8.exeSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN100 PC Version SW M007-1.1.0.8.zipSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN100 PC Version SW M007-1.1.0.9.exeSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN100 PC Version SW M007-1.1.0.9.zipSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN100 latest windows software with Drivers.zipCopy this directory locally, the latest SW version is included. Add other ESN100 PC software versions as required
The windows versions of the Multi software (Not web version) can be started using a script as follows
Start the software manually, set the LAN settings
Then use a script to start the window:
Remove the windows border : -frameless-window , the program can be killed using alt+F4
Use the saved LAN settings : -load-net-interface
Maximise the window : -maximize-window
to save the current LAN settings: -save-net-interface
Example to start automatically
start multi_screen.exe -load-net-interface -maximize-window -frameless-window
to start to select new LAN settings
Start multi_screen.exe -save-net-interface -maximize-window -frameless-window
Older versions
ESN100 PC Version SW M007-1.0.4.0.exe
The windows versions of the Multi software (Not web version) requires the ESNDrivers to be copied locally, and then this file can be copied into that directory
Select the same software version as you are running on the display
ESN100 PC Version SW M007-1.0.4.0.rar
The windows versions of the Multi software (Not web version) requires the ESNDrivers to be copied locally, and then this file can be copied into that directory
Select the same software version as you are running on the display
ESN100 PC Version SW M007-1.0.4.0.zip
The windows versions of the Multi software (Not web version) requires the ESNDrivers to be copied locally, and then this file can be copied into that directory
Select the same software version as you are running on the display
ESN100 PC Version SW M007-1.1.0.0.exe
ESN100 PC Version SW M007-1.1.0.0.zip
ESN100 PC Version SW M007-1.1.0.4.exe
ESN100 PC Version SW M007-1.1.0.4.zip
ESN100 PC Version SW M007-1.1.0.5.exe
ESN100 PC Version SW M007-1.1.0.5.zip
ESN100 PC Version SW M007-1.1.0.6.exe
ESN100 PC Version SW M007-1.1.0.6.zip
ESN100 1 0 3 c.rar
Older versions
SW M007 1 0 1 ESN100 software.tarRecomended Software update for ESN100 This software includes improvements in Auto functions and a number of bug fixes.
SW M007 1 0 3 0 Software for ESN100 Display.tarSoftware update for ESN100 1.01.03 - This is a new type of upgrader and the files do not need to be unzipped. Use the latest skipper service software and go to ESN100 tab for further instructions.
SW M007 1 0 4 0 Software for ESN100 Display.tarSoftware update for ESN100 1.01.04 -
This is a new type of upgrader and the files do not need to be unzipped. Use the latest skipper service software and go to ESN100 tab for further instructions.
1.0.4.0 changes History to 24h (previously 12h), adds printer menu, and option to turn on and off the LAN printer (runs with service software or ESN print and archive software that can be downloaded from the website), and gives option to download the previous 2 days history.
New manual also available
New service software 1.88 , will also download a stand alone .exe in the skipper/service software folder, ESN print and archive software V1.0.1 that can run in stand alone mode
SW M007 1 1 0 8 ESN100.tar
ESN100 1.1.0.8 (14.11.2022)
correct error in UDP (sending too many messages on different groups)
Added a fixed number (8) in message PSKPDPT for signal strength
ESN100 1.1.0.7 (3.11.2022)
fix of clock input
adjust ment of max ping to prevent power baterry emptying
Remove noise from screen introduced in 1.1.0.5
ESN100 1.1.0.6 (3.10.2022)
bug fix of noise on screen
improvement of deep water power output in 200kHz

ESN100 1.1.0.6 (30.09.2022)
Added HBT on second Alarm UDP group
bug fix of beeper beeping unevenly, particularly when range changes.

ESN100 1.1.0.5 (23.09.2022)
Improvement of logging function - longer logging period of raw data
Memory/CPU over useage corrected
Noise test summary on diagnostic page is corrected
UDP s: d: order is now not important
UTC/LOC time is corrected

ESN100 1.1.0.4 bugfix
Transducer 2 shows Transducer 1 information (from 1.1.0.1)
Problem with receiveing ZDA clock (from 1.1.0.1)
ESN100 1.1.0.2 bugfix
Removed occasional popup for 2 transducers
ESN100 1.1.0.1 bugfix
speed of sound function changes
addition of EPV standby and remote control
Recomended Software update for ESN100 1.1.0
Includes the new Alert standard IEC62923 BAM standard with alerts. A new Manual and Type certificate is also available.
Previously 1.0.4.0
This is a new type of upgrader and the files do not need to be unzipped. Use the latest skipper service software and go to ESN100 tab for further instructions.
1.0.4.0 changes History to 24h (previously 12h), adds printer menu, and option to turn on and off the LAN printer (runs with service software or ESN print and archive software that can be downloaded from the website), and gives option to download the previous 2 days history.
New manual also available
New service software 1.88 , will also download a stand alone .exe in the skipper/service software folder, ESN print and archive software V1.0.1 that can run in stand alone mode
1.0.3.0 included improvements in Auto functions and a number of bug fixes
Last Update 30.9.2022
SW M007 1 1 0 9 ESN100.tar
ESN100 1.1.0.9 (26.05.2023)
Correction of Local or UTC clock, if the offset in ZDA is -00
Added a variable number (8) in message PSKPDPT for the number of sequential fully qualified pings (0-9) this can be used as quality of the signal
ESN100 1.1.0.8 (14.11.2022)
correct error in UDP (sending too many messages on different groups)
Added a fixed number (8) in message PSKPDPT for signal strength
ESN100 1.1.0.7 (3.11.2022)
fix of clock input
adjust ment of max ping to prevent power baterry emptying
Remove noise from screen introduced in 1.1.0.5
ESN100 1.1.0.6 (3.10.2022)
bug fix of noise on screen
improvement of deep water power output in 200kHz

ESN100 1.1.0.6 (30.09.2022)
Added HBT on second Alarm UDP group
bug fix of beeper beeping unevenly, particularly when range changes.

ESN100 1.1.0.5 (23.09.2022)
Improvement of logging function - longer logging period of raw data
Memory/CPU over useage corrected
Noise test summary on diagnostic page is corrected
UDP s: d: order is now not important
UTC/LOC time is corrected
ESN100 1.1.0.4 bugfix
Transducer 2 shows Transducer 1 information (from 1.1.0.1)
Problem with receiveing ZDA clock (from 1.1.0.1)
ESN100 1.1.0.2 bugfix
Removed occasional popup for 2 transducers
ESN100 1.1.0.1 bugfix
speed of sound function changes
addition of EPV standby and remote control
Recomended Software update for ESN100 1.1.0
Includes the new Alert standard IEC62923 BAM standard with alerts. A new Manual and Type certificate is also available.
Previously 1.1.0.0
This is a new type of upgrader and the files do not need to be unzipped. Use the latest skipper service software and go to ESN100 tab for further instructions.
1.0.4.0 changes History to 24h (previously 12h), adds printer menu, and option to turn on and off the LAN printer (runs with service software or ESN print and archive software that can be downloaded from the website), and gives option to download the previous 2 days history.
New manual also available
New service software 1.88 , will also download a stand alone .exe in the skipper/service software folder, ESN print and archive software V1.0.1 that can run in stand alone mode
1.0.3.0 included improvements in Auto functions and a number of bug fixes
Last Update 26.5.2023
ESN200 - Software for ESN200 echosounder
ESN200 1.1.5.0 - Software for ESN200 echosounder.zipContaining latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .ZIP and use the SW-M0XXX.tar files, do not unpack these.
SW-M008-1.1.5.0 & SW-M010-1.1.5.0, based on version 1.1.4.7 withthe following major changes.
Fix of UTC/Loc time
addition of PSKPDPT1 and 2 to allow PSKPDPT sentences to be sent separately on each NMEA, allowing use of IR301 and other older repeaters.
PSKPDPT now has a quality parameter
BAM & ALF improvements
improvements of LWE -450 messages
Memory and slowdown bug fixes
New manual

Last Updated 13.4.2023
Instruction for upgrade of Multi systems.pdfSome instruction for use with upgrade of Multi systems using the SKIPPER service software. <\BR> It is important that the software version in the screen and the electronic unit match. If you are replacing 1 unit , check you have the same software version, and if not update the older part.
LICENSE.lgpl-2.1.pdfSKIPPER software uses a number of Open source programs, under license type LICENSE.lgpl-2.1. This file explains and clarifies the use of the software under this license.
Equivilent Software for Windows
ESN200 Latest windows software with Drivers.zipCopy this directory locally, this includes the latest software version, add other ESN200 PC version as required
The windows versions of the Multi software (Not web version) can be started using a script as follows
Start the software manually, set the LAN settings
Then use a script to start the window:
Remove the windows border : -frameless-window , the program can be killed using alt+F4
Use the saved LAN settings : -load-net-interface
Maximise the window : -maximize-window
to save the current LAN settings: -save-net-interface
Example to start automatically
start multi_screen.exe -load-net-interface -maximize-window -frameless-window
to start to select new LAN settings
Start multi_screen.exe -save-net-interface -maximize-window -frameless-window
ESN200 Windows 1.1.5.0.exeSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN200 Windows 1.1.5.0.zipSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
Older versions
ESN200 PC Version 1 0 6.exe
The windows versions of the Multi software (Not web version) requires the ESNDrivers to be copied locally, and then this file can be copied into that directory
Select the same software version as you are running on the display
ESN200 PC Version 1 0 7.exe
ESN200 PC Version 1 0 7.zip
ESN200 Windows 1.1.2.0.exe
ESN200 Windows 1.1.2.0.zip
ESN200 Windows 1.1.3.0.exe
ESN200 Windows 1.1.3.0.zip
ESN200 Windows 1.1.4.0.exe
ESN200 Windows 1.1.4.0.zip
ESN200 Windows 1.1.4.2.exe
ESN200 Windows 1.1.4.2.zip
ESN200 Windows 1.1.4.3.exe
ESN200 Windows 1.1.4.3.zip
ESN200 Windows 1.1.4.4.exe
ESN200 Windows 1.1.4.4.zip
ESN200 Windows 1.1.4.5.exeSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
ESN200 Windows 1.1.4.5.zipSoftware only, to be placed in the driver folder preferably in c:\skipper\ESN200\. If you do not have this folder use the other .zip file with drivers included
Older versions
ESN200 1.1.4.3 Software for ESN200 echosounder.zip
ESN200 SW 1.1.2.0 - Software for ESN200 echosounder.rarContaining latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .RAR and use the SW-M0XXX.tar files, do not unpack these.
SW-M010-1.1.2.0 & SW-M008-1.1.2.0, fixed issues with ALR, New EPV remote control features, Fixes on Printer parameters, New Synch - ready to ping, - New Manual
SW-M010-1.1.0.0 & SW-M008-1.1.0.0 Complient with IEC62923 BAM standard, and IEC61162-450. Many changes - check the manuals
New text printer added Epson TM-T20III
SW-M010-1.0.7.0 & SW-M008-1.0.7.0 Added LAN printer(vis service software or APP) and ML1120 printer. Improvements of Diagnostics and bottom detection algorithm
Added Transducer KMS5018 selection, added options for DPT Max range, added Multiplex mode for ch1 and ch2 for using 2 transducers with the same frequency, extended internal history to 24h
SW-M010-1.0.6.2 black box software with fixes for shallow water, bug fix of untis in DBS,DBT,DBK NMEA sentences
SW-M010-1.0.6.1 black box software with fixes for shallow water, Diagnostic page, power failure on relay, Draft, NMEA2 input, other small bugs
SW-M008-1.0.6.0 Display software with improvments in shallow water detection
SW-M008-1.0.5.0 Display software with a number of gui improvements particularly in the diagnostics pages, SNR value (bottom detection threshold) can now be adjusted from scope screen.
SW-M0010-1.0.5.0 black box software with a number of improvements in bottom detection , and fix for jumping depth to zero, new settings levels.
SW-M008-1.0.4.0 Display software with a number of gui improvements and diagnostics improvements, improvement of TVG
SW-M010-1.0.4.0 Electronic unit software with improvements in filter, depth detction, range, TVG and noise rejection
Update using via LAN cable and Service software, ensure your PC is set up for static IP address in the same range as the unit (172.16.1.XXX)
Last updated 30.08.2021
ESN200 SW 1.1.3.0 Software for ESN200 echosounder.zip
ESN200 Software for ESN200 Echosounder 1.0.7.zipContaining latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .zip and use the SW-M0XXX.tar files, do not unpack these.
SW-M010-1.0.7.0 & SW-M008-1.0.7.0 Added LAN printer(vis service software or APP) and ML1120 printer. Improvements of Diagnostics and bottom detection algorithm
Added Transducer KMS5018 selection, added options for DPT Max range, added Multiplex mode for ch1 and ch2 for using 2 transducers with the same frequency, extended internal history to 24h
SW-M010-1.0.6.2 black box software with fixes for shallow water, bug fix of untis in DBS,DBT,DBK NMEA sentences
SW-M010-1.0.6.1 black box software with fixes for shallow water, Diagnostic page, power failure on relay, Draft, NMEA2 input, other small bugs
SW-M008-1.0.6.0 Display software with improvments in shallow water detection
SW-M008-1.0.5.0 Display software with a number of gui improvements particularly in the diagnostics pages, SNR value (bottom detection threshold) can now be adjusted from scope screen.
SW-M0010-1.0.5.0 black box software with a number of improvements in bottom detection , and fix for jumping depth to zero, new settings levels.
SW-M008-1.0.4.0 Display software with a number of gui improvements and diagnostics improvements, improvement of TVG
SW-M010-1.0.4.0 Electronic unit software with improvements in filter, depth detction, range, TVG and noise rejection
Update using via LAN cable and Service software, ensure your PC is set up for static IP address in the same range as the unit (172.16.1.XXX)
Last updated 04.03.2020
SW for ESN200 1.1.0 w BAM changes.zipContaining latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .zip and use the SW-M0XXX.tar files, do not unpack these.
SW-M010-1.1.0.0 & SW-M008-1.1.0.0 Complient with IEC62923 BAM standard, and IEC61162-450. Many changes - check the manuals
New text printer added Epson TM-T20III
SW-M010-1.0.7.0 & SW-M008-1.0.7.0 Added LAN printer(vis service software or APP) and ML1120 printer. Improvements of Diagnostics and bottom detection algorithm
Added Transducer KMS5018 selection, added options for DPT Max range, added Multiplex mode for ch1 and ch2 for using 2 transducers with the same frequency, extended internal history to 24h
SW-M010-1.0.6.2 black box software with fixes for shallow water, bug fix of untis in DBS,DBT,DBK NMEA sentences
SW-M010-1.0.6.1 black box software with fixes for shallow water, Diagnostic page, power failure on relay, Draft, NMEA2 input, other small bugs
SW-M008-1.0.6.0 Display software with improvments in shallow water detection
SW-M008-1.0.5.0 Display software with a number of gui improvements particularly in the diagnostics pages, SNR value (bottom detection threshold) can now be adjusted from scope screen.
SW-M0010-1.0.5.0 black box software with a number of improvements in bottom detection , and fix for jumping depth to zero, new settings levels.
SW-M008-1.0.4.0 Display software with a number of gui improvements and diagnostics improvements, improvement of TVG
SW-M010-1.0.4.0 Electronic unit software with improvements in filter, depth detction, range, TVG and noise rejection
Update using via LAN cable and Service software, ensure your PC is set up for static IP address in the same range as the unit (172.16.1.XXX)
Last updated 30.08.2021
SW-M008-1.1.4.5 Software for ESN200.zipContaining latest SW version for ESN200 Display (ESN200-SB) and Electronic unit (JB70E2) and manual, Unpack the .ZIP and use the SW-M0XXX.tar files, do not unpack these.
SW-M008-1.1.4.5 & SW-M010-1.1.4.5, Fixes in BAM, beeping, HBT and s:/d: order, bug fixes in GPS NMEA inputs
Also including
1.1.4.4 Fixes in UTC and local clock, Logging of raw data, small bugs
1.1.4.3 Fixes in GPS local time, Line printer formats, Logging to USB and internal logging.
1.1.4.2 Bugfix transducer runtime screen for second channel showed first channel again (since 1.1.4.0)
1.1.4.1 Bugfix Display had problems showing clock for NMEA port with ZDA sentence (since 1.1.3.0)
SW-M010-1.1.4.0 & SW-M008-1.1.4.0,
- ETS50200 transducer is limited to 70% on 200kHz and 60% on 50kHz. ETN50 ETN200S Are limited to 70%, ETS050 is limited to 60%, ETS200 is limited to 70%.
- Various bugfixes.
Last Updated 28.10.2022
ETT985 - Tester firmware upgrade software
RS232 USB DRIVERS.zipZipped file of the installation drivers for the pink USB_232 converter supplied with ETT985
STARTUPFILE
STARTUP.EXE
SkipperServiceSoftware
Read.MeDesember-21 Release notes Current version Version 1.96
SetupProjectServiceSoftware.msiInstallation file for SKIPPER Service Software, for use with ETT985 and other SKIPPER products (self-signed cert)
Welcome.html

Welcome to the new SKIPPER Service software.

This software is designed to provide software support on SKIPPER products. The software will upgrade itself whenever something new is available, and SKIPPER development are working on methods of performing diagnostic, upgrades, and help on new and existing products. As well as news and change notifications.

If available, the software can be plugged into the supported products either directly using RS232, using an NMEA adapter or the ETT tester which contains a converter, or in newer products, via LAN. The softwares can then be used to monitor the devices and a fix, or suggest improvements.

If you want to you can make the software download all the latest softwares on to your local machine so that you can upgrade in the field.

This version currently contains interfaces to EML224 sensor, NMEA inputs and outputs and the ETT985 tester, for testing echosounders and transducers. Speed Log Compact EML224 and DL1 in addition to Speed Log Multi DL1, DL2 and DL21. Sat Log SL1200 including Sat Log Display SD21 and S2. Echo Sounder ESN100 and ESN200. IR31DIM NMEA Remote Dimmer Panel

New Products will be released with an update of this software.

Speed log analysis software
Graphlog.rarMulti DL2 and DL21 analysis software V3.04
Load in the data recorded by putting a USB stick into a DL2 (DL21) unit
Look at raw data, the data as the customer saw it, change the calibration and see what it looks like.